WASTEWATER TREATMENT SYSTEMS

TRICEL MAXUS WASTEWATER TREATMENT

Overview

The Tricel Maxus operates on Submerged Aerated Filter (SAF) Technology. The Plant is controlled by the E-III control panel through which all electrical components are connected.

They are robust and easy to install, with multiple configurations that suit any site.

Simple in operation, they are easy to maintain over the product’s lifespan.

​Applications include:

to name a few.

These highly versatile systems are individually sized to suit every scenario over 50PE.

KEY FEATURES AND BENEFITS OF THE TRICEL MAXUS WASTEWATER TREATMENT

Wastewater treatment is suitable for more than 50 Population Equivalent (PE) applications.

  • Excellent treatment from proven SAF technology.
  • Ideal for seasonal loads or constant loads. The control panel will automatically adjust to the incoming load to ensure optimum performance.
  • Extensively tested and ETA verified for holiday home applications. The system will go into a power-saving mode during periods of no flow and restart once a flow is detected without the need for any manual inputs.
  • Swift back up and service located in Ireland. Range of service contracts available.
  • Full design engineered solutions are offered. Bespoke solutions are offered for every unique site to ensure the best performance. GRP or Concrete settlement tank options.
  • Flexible installation options to suit any site. This plant can fit into difficult sites or simply save space.
  • Versatile technology which can adapt to different loadings or effluent strengths.
  • Simple operation using long-life reliable components leads to low running costs. No moving parts within the plant make it easy to maintain.

HOW DOES THE TRICEL MAXUS WORK?

The wastewater treatment Tricel Maxus utilizes highly effective SAF technology, treating wastewater in 4 stages.

1. The settlement tank:

Wastewater enters into the Tricel Maxus System in the settlement tank. Here, primary treatment occurs. Heavy solids are separated from the wastewater and settle out to form a sludge on the tank’s base. Lighter solids, such as oil fats, or grease, float to the top of the wastewater and are retained within the settlement tank.

2. The buffer tank:

From here, the partially treated wastewater enters the buffer tank. The buffer tank will even out any fluctuations in the incoming water load. Pumps at the buffer tank’s bottom feed the wastewater into the treatment plant.

3. The biological treatment zone:

In this zone, the submerged aerated filter, with a large surface area for the microbes, is exposed to heavy aeration as the wastewater passes through. The system will never clog and does not need any maintenance or chemicals.

4. The clarifier:

In the clarifier, bio sludge from the treatment process settles out of the treated liquid. Airlift pumps recirculate the bio sludge from the base of the tank back to the settlement tank. The fully treated liquid is now ready to discharge from the plant.

The settlement and buffer tanks

TECHNICAL CHARACTERISTICS AND PLANT DIMENSIONS

The table below shows Tricel Maxus system sizes, but each system is designed to suit project requirements.

<td”>285J75X2<td7.902.162.22

CodePESettlement And Buffer Tank* (1+2)   Treatment Plant (3+4)   
  TankL (M)W (M)H (M)Plant shape**L (M)W (M)H (M)
66M500066Settlement6.601.642.05Circular2.002.002.20
  Buffer1.601.642.05    
88M600088Settlement6.601.642.05Circular2.302.302.20
  Buffer3.601.642.05    
112J25112Settlement6.601.642.05Rectangular2.802.162.22
  Buffer6.601.642.05    
154J50154Combined5.702.872.70Rectangular3.302.162.22
175J75175Combined6.172.872.70Rectangular3.952.162.22
238J100238Combined9.052.872.70Rectangular5.452.162.22
294J50X2294Combined10.892.872.70Rectangular6.602.162.22
385Combined14.122.872.70Rectangular
560J100X2560Settlement9.952.872.70Rectangular10.902.162.22
  Buffer9.952.872.70    

Dimensions of Tricel Maxus Wastewater Treatment Systems.
*All settlement and buffer tank dimensions are for GRP tanks as standard. Concrete options are available.
** Please note, the treatment plant is circular for up to 88PE and rectangular for plants over 88PE.